Welcome to the Elephant Central building safety works information page

Here you will find information for each building at Elephant Central, along with other useful information.

Last updated: 12/10/2026

We are carrying out a programme of building safety works which will focus on areas such as external walls, balconies and some internal fire safety measures.

The assessments confirm that residents are safe to remain in their home while the planned works are carried out. Additional fire safety measures are in place while we prepare for the works, including an enhanced fire alarm system.

We will be working closely with our specialist contractors, Pavehall, to complete the works safely and efficiently, while doing everything we can to minimise disruption to residents.

Before works to the buildings can begin, we are awaiting final approval from the Government’s Building Safety Regulator. We expect to receive this approval very soon.

The evacuation strategy for Mawes House, Tantallon House and Raglan House is Simultaneous Evacuation. This means you must evacuate immediately when you hear the fire alarm.

Building information

Key contacts

Caoimhe, Resident Liaison Officer, Pavehall

You can contact Caoimhe at Pavehall on mobile at +44 (0)7375 688 864 for further information about the programme of works.

To speak to the Get Living team about the works please use the following address: [email protected]

Mawes House

The fire strategy for Mawes House is Simultaneous Evacuation. This means you must evacuate immediately when you hear the fire alarm.

Key building information

The building  FRA and external wall appraisal have different purposes. The FRA considers fire precautions and management within the common parts. The FRAEW specifically assesses fire spread risk through the external wall. Actions identified through either assessment are tracked and reviewed as part of the building safety programme.

The assessment covered the common parts and recorded an overall fire risk rating of ‘Moderate’. It identified 10 improvement actions and no Priority 1 actions. 

NB: Priority 1 actions are those that need to be urgently addressed within 24 hours.

The FRAEW assessed the existing external wall condition as requiring remediation. Therefore, works are required to replace specified combustible materials and reduce the external wall risk to a tolerable level.

The specialist external wall appraisal identified materials that require replacement to achieve a tolerable risk rating.

  • Replace the existing material in the panels between windows with a safer, non-combustible material to improve fire safety.
  • Replace the existing material in and around balcony door panels with a safer, non-combustible material.
  • Replace timber balcony decking.
  • Address cavity barrier matters where required.  Additional investigations found cavity barriers generally in place and mineral wool insulation behind the limestone cladding.

Scaffolding works are underway on Ash Avenue and will continue through October, as works progress around the building.

  • Temporary simultaneous evacuation strategy, supported by fire action information for residents.
  • Automatic fire detection and warning in the areas assessed, with routine testing and servicing records reviewed.
  • Automatic Opening Ventilation (AOV) and smoke control serving escape routes.
  • A common protected stairwell, a main final exit and an alternative exit from the third-floor landing into the central courtyard.
  • A firefighting lift, wet rising main, sprinkler system, emergency lighting and refuge communication points.
  • 24-hour security presence and regular property checks.

  1. Leave the building when the alarm sounds and follow the current fire action information.
  2. Keep corridors, lobbies and stairs free from belongings.
  3. Do not wedge fire doors open. Report damage or doors that do not close.
  4. Do not interfere with detectors, sounders or sprinklers in your room.
  5. Use manufacturer-approved chargers and never charge damaged batteries.
  6. Tell the building team if you may need additional support in an emergency.

Raglan House

The fire strategy for Raglan House is Simultaneous Evacuation. This means you must evacuate immediately when you hear the fire alarm.

Key building information

The building FRA and external wall appraisal have different purposes. The FRA considers fire precautions and management within the common parts. The FRAEW specifically assesses fire spread risk through the external wall. Actions identified through either assessment are tracked and reviewed as part of the building safety programme.

The assessment covered the common parts of Raglan House. It recorded an overall ‘Tolerable’ fire risk rating, with 10 actions and no Priority 1 actions.

NB: Priority 1 actions are those that need to be urgently addressed within 24 hours.

The appraisal found that the current external wall position is tolerable, but identified specific matters at balcony decking and the stair core interface that require remediation works.

The following work is required and is being taken forward in the upcoming programme of works:

  • Replace timber balcony decking.
  • Fully review and remediate the compartment interfaces between the escape stair, adjacent flats and the façade –
  • Remove combustible materials from identified cavities.
  • Install or repair horizontal fire stopping and missing vertical cavity barriers.
  • Close openings from cavities into the escape stair compartment and update the fire strategy where necessary.

Preparatory surveys are taking place ahead of scaffolding to Raglan House. Scaffolding will follow as the works move to this section of Elephant Road.

  • Temporary simultaneous evacuation strategy and fire action information.
  • Automatic fire detection and warning, with testing and servicing records reviewed.
  • Automatic opening ventilation and smoke control serving escape routes.
  • A protected lobby route leading to a single common staircase, with alternative access through the third-floor central garden.
  • A firefighting lift, rising main, sprinklers within flats, emergency lighting and refuge communication points.
  • 24-hour security patrols across the development and arrangements to escalate fire safety faults.

  1. Leave the building when the alarm sounds and follow the current fire action information.
  2. Keep corridors, lobbies and stairs free from belongings.
  3. Do not wedge fire doors open. Report damage or doors that do not close.
  4. Do not interfere with detectors, sounders or sprinklers in your room.
  5. Use manufacturer-approved chargers and never charge damaged batteries.
  6. Tell the building team if you may need additional support in an emergency.

Tantallon House

The fire strategy for Tantallon House is Simultaneous Evacuation. This means you must evacuate immediately when you hear the fire alarm.

Key building information

The building FRA and external wall appraisal have different purposes. The FRA considers fire precautions and management within the common parts. The FRAEW specifically assesses fire spread risk through the external wall. Actions identified through either assessment are tracked and reviewed as part of the building safety programme.

The assessment covered the common parts and recorded an overall fire risk rating of ‘Moderate’. It identified 10 improvement actions and no Priority 1 actions.

NB: Priority 1 actions are those that need to be urgently addressed within 24 hours.

The appraisal found that the current external wall position is tolerable, but identified specific matters at balcony decking and the stair core interface that require remediation works.

The following work is required and is being taken forward in the upcoming programme of works:

  • Replace the timber balcony decking with non-combustible material.
  • Fully review and remediate the compartment interfaces between the escape stair, adjacent flats and the façade.
  • Remove the combustible materials from identified cavities.
  • Install or repair horizontal fire stopping and missing vertical cavity barriers.
  • Close the openings from cavities into the escape stair compartment and update the fire strategy where necessary.

Preparatory surveys are taking place ahead of scaffolding to Tantallon House. Scaffolding will follow as the works move to this section of Elephant Road.

  • A temporary simultaneous evacuation strategy.
  • Automatic fire detection and warning, with testing and servicing records reviewed.
  • Automatic opening ventilation and smoke control serving escape routes.
  • A protected lobby route leading to a single common staircase, with alternative access through the third-floor central garden.
  • A firefighting lift, rising main, sprinklers within flats, emergency lighting and refuge communication points.
  • 24-hour security patrols across the development and arrangements to escalate fire safety faults.

  1. Leave the building when the alarm sounds and follow the current fire action information.
  2. Keep corridors, lobbies and stairs free from belongings.
  3. Do not wedge fire doors open. Report damage or doors that do not close.
  4. Do not interfere with detectors, sounders or sprinklers in your room.
  5. Use manufacturer-approved chargers and never charge damaged batteries.
  6. Tell the building team if you may need additional support in an emergency.

Portchester House

Portchester House is currently vacant while remediation works are underway.